A926_O: Inverter Fault - HP Sensor not Configured

EcoNet - A926_O ยป

Status

This is a critical alarm, the unit will not operate in any mode.

Description

This code is displayed anytime the UODC (Universal outdoor control) is missing specific model data.

Expected Operation

No operation.

Cause

Model data has been updated with the wrong file, a component has been changed which does not match the pre-existing model data, or model data was not loaded (for example into a replacement control).

Solution

Use the Contractor App to update model data.

If problem persists, replace UODC (Universal Outdoor Unit Control).