A925_O: Inverter Fault - Compressor Model Unknown

EcoNet - A925_O ยป

Status

This is a critical alarm, the unit will not operate in any mode.

Description

This code is displayed anytime the UODC (Universal outdoor control) is missing specific compressor model data.

Expected Operation

No operation.

Cause

Thermostat Firmware does not have functionality to drive equipment with its older firmware.

Solution

1. This fault is likely due to missing or corrupted model-specific information. Technician should use the Contractor App to restore model data.

2. If problem persists, replace UVSODU controller.

3. If model data files are correct and UVSODU controller is OK, replace inverter drive controller.