A813_O: Inverter- IPM Sampling Fault
Status
No operation when Alarm is Present. Operation will resume if Alarm clears. After three strikes without 15 minutes of continuous operation, a permanent lockout (requiring power reset) will occur.
Description
Compressor drive has declared an internal fault and cannot detect a temperature sensor connected to the internal power module.
Expected Operation
Critical Fault - No operation until corrected.
Cause
Compressor drive cannot read the temperature of the internal power module.