A998_O: Fan Motor Parameter Fault

EcoNet - A998_O ยป

Status

Unit will not operate while fault is active.

Description

Drive is detecting problem with fan motor parameters.

Expected Operation

No operation.

Cause

Fan data has been updated with the wrong file, fan has been changed which does not match the pre-existing fan data, or fan data was not loaded (for example into a replacement control).

On early versions of UODC firmware, powering up the indoor unit before the outdoor unit.

Solution

This may be corrected simply by cycling the power off to both the indoor and outdoor unit and returning power to the outdoor unit first and then the indoor. 