EcoNet Compatibility
What Equipment is compatible with an EcoNet Thermostat?
HVAC
Important: The 700 Series EcoNet Thermostat is NOT compatable with the new M1 product designed for the new 2023 standard. You must use the 800 Series EcoNet Thermostat for new M1 Products.
Air Handlers
Note: Outdoor unit must be EcoNet compatible when matched with an air handler. Non-Communicating outdoor units cannot be matched with an EcoNet communicating air handler.
Outdoor Units
Gas Furnaces
Gas Furnaces with Non-Communicating Outdoor Units
Communicating gas furnaces may be matched with non-communicating outdoor units. Outdoor unit is wired to legacy terminals of the gas furnace. If system is dual fuel, an outdoor sensor may be wired back to the gas furnace to provide balance point changeover settings.
CC2 Translator
EcoNet compatible Gas furnaces may be paired with earlier JEC / CC2 Communicating products as long as an RETRN620CC2 translator is installed in the outdoor unit. This includes (-)ARL-JEC, (-)ASL-JEC and (-)PRL-JEC outdoor units.