A812_O Inverter-Drive Failure
Status
No operation when Alarm is Present. Operation will resume if Alarm clears. After three strikes without 15 minutes of continuous operation, a permanent lockout (requiring power reset) will occur.
Description
Compressor drive has declared an undefined internal error.
Expected Operation
Critical Fault - No operation until corrected.
Cause
Internal error declared by the compressor drive.
Solution
- Check and correct wiring and electrical connectors to drive and compressor
- Replace Compressor Drive.
- Replace compressor.