Portal econet_A827_O_M1

A827_O: Inverter- IPM Temp Sense Failure

EcoNet - A827_O ยป

Status

No operation when Alarm is Present. Operation will resume if Alarm clears.

Description

Compressor drive has detected a fault with the internal power module (IPM) temperature sensor - the sensor has failed or is no longer detected.

Expected Operation

Critical Fault - No operation until corrected.

Cause

Compressor drive can no longer detect the internal power module temperature sensor.

Solution

  • Check and correct wiring and electrical connectors to drive and compressor.
  • Replace Compressor Drive.
  • Replace compressor.