Air Handler Alarms and Alerts
Which Alarm do you have?
Indoor
When looking at fault codes, especially at the EcoNet thermostat, pay close attention to the verbiage and the suffix at the end. Don't allow yourself to be chasing a rabbit down the wrong hole by looking at a fault that may be in the indoor equipment by just using the numbers.
Anytime you report a fault to your distributor, provide the complete fault description, not just the number.
_O means Outdoor Unit
_A means Air Handler
_F means Furnace
_C means Communication
_S means System
You must navigate to the appropriate product to read faults related to it. For instance if you are looking for a fault that ends in _A, you are at the right place. If you are looking for a fault that ends in _O, then you will need to go back and select the appropriate outdoor unit to see the faults that are listed with it. Alarms ending in _C or _S are found under the thermostat alarms and alerts.
The Alarm or Alert I have is...
A001_A: Model Data Configuration Error
A002_A: Blower Coefficients Missing
A021_A: Restricted Airflow-Possible Frozen Coil
A031_A: Open Fuse
A051_A: Refrigerant Leak Sensor 1 Comm Fault
T081_A: Return Air Sensor Fault
T082_A: Supply Air Sensor Fault
T084_A: Outdoor Air Sensor Fault
T085_A: Evap Temp Thermistor Failure
T086_A: Suction Pressure Sensor Failure
A093_A: Model Data Restore Failure
A100_A: Configuration Data Restore Failure
A101_A: ECM Blower Motor Communication Failure
A102_A: ECM Power Level doesn't match Memory Card
A103_A: Memory Card Config Data Write Failure
A104_A: ECM Blower Motor Run Fault
A105_A: ECM Blower Fault - Incomplete Parameters
A106_A: Memory Card Static Pressure Data Failure
A107_A: Return Air Temp Thermistor Failure
A108_A: Leaving Air Temp Thermistor Failure
A109_A: Suction Pressure Sensor Failure
A110_A: Evap Temp Thermistor Failure
A111_A: EXV Temp Thermistor Failure
A112_A: Water Inlet Thermistor Failure
A113_A: No Evap or Suction Press. Sensor Failure
T114_A: Heater Size Indeterminate
T115_A: EXV Sensor Measurement Error
A116_A: Heater Size Too Large For Air Handler
T117_A: Detect RPM Motor Failure
A201_A: Float Switch Trip - Air Handler CS or Aux 1 In 1
A203_A: Float Switch Trip - Air Handler Aux In 2
A206_A: Electric Heat Lockout - Aux Input 1
A207_A: Hydronic Heat Lockout - Aux Input 1
A209_A: Electric Heat Lockout - Aux Input 2
A210_A: Hydronic Heat Lockout - Aux Input 2
A211_A: Shutdown Cooling - Air Handler Aux Input 1
A213_A: Shutdown Cooling - Air Handler Aux Input 2
A215_A: Shutdown System - Air Handler Aux Input 1
A217_A: Shutdown Cooling - Air Handler Aux Input 2
A219_A: Heat Pump Lockout - Air Handler Aux Input 1
A221_A: Heat Pump Lockout - Air Handler Aux Input 2
A311_S: Indoor Unit Refrigerant Detected Sensor 1
A315_S: Indoor Refrigerant Detected Sensor 1
NOTE:
Some alarms or alerts such as the A202_A and A203_A may appear as duplicates but the alarm codes may have been changed depend on which version of firmware is in the equipment or thermostats as some have been updated along the way.