Outdoor Alarms and Alerts
(-)A19AY and (-)P19AY Inverters
Which Alarm do you have?
Outdoor
Alarms begin with an A, and are in red buttons
Alerts begin with a T, and are in yellow buttons
When looking at fault codes, especially at the EcoNet thermostat, pay close attention to the description and the suffix at the end. Don't chase a rabbit down the wrong hole by looking at a fault and not knowing which unit has the fault.
Anytime you report a fault to your distributor, provide the complete fault code and description, not just the number.
_O means Outdoor Unit
_A means Air Handler
_F means Furnace
_C means Communication
_S means System
_Z means Zoning
If you are looking for faults related to the Outdoor unit, you are in the right place because the fault ends in _O. If you are looking for a fault that has a suffix other than _O, you will need to use your back button and navigate to the appropriate product family to see alarms for those.
The Alarm or Alert I need help with is...
A001_O: Model Data Configuration Error
A002_O: Compressor Model Data Error
A003_O: Fan Model Data Error
A004_O: Econet Thermostat Version Not Compatible
T011_O: Pressure Relief Valve Stuck Closed
T012_O: Pressure Relief Valve Stuck Open
A093_O: Model Data Restore Failure
A111_O: Communications Lost with Indoor Unit
A112_O: Expected Econet IDU Not Connected
T113_O: Expected Econet IDU Not Connected
T114_O: Liquid Temp Thermistor Failure
T115_O: EXV Sensor Measurement Error
T116_O: Suction Pressure Floodback Protection
A121_O: Time Clock Not Advancing Time Properly
A811_O: Inverter-IPM Fault
A812_O: Inverter-Drive Failure
A813_O: Inverter- IPM Sampling Fault
A814_O: Inverter-AC Input Sampling Fault
A815_O: Inverter- Fan 1 Fault
A816_O: Inverter- Fan 2 Fault
A817_O: Inverter- Rect. Bridge Temp Sensor
A818_O: Inverter- Rect. Bridge Temp Sensor
A819_O: Inverter- DC Overvoltage Logic Fault
A821_O: Inverter- DC Undervoltage Logic Fault
A822_O: Inverter- Rect. Bridge Overtemp Fault
A823_O: Inverter- AC Overvoltage Logic Fault
A824_O: Inverter- Compressor Reversed Connection
A825_O: Inverter- AC Input Overcurrent
A826_O: Inverter- AC Input Phase Fault
A827_O: Inverter- AC IPM Temp Sense Failure
A828_O: Inverter- EEPROM Failure
T901_O: Inverter Fault - Comp. Overcurrent
T911_O: Inverter Fault - Lost Rotor Position
A912_O: Inverter Fault - Self Check Fault
T913_O: Contactor Not Closing
T914_O: Inverter Fault - DC Voltage Low
A915_O: Inverter Fault - Comm Fault
T916_O: Inverter Fault - Discharge Line Temp
T917_O: Inverter Fault - PIM Temp
T918_O: Inverter Fault - PFC Temp
A920_O: Inverter Fault - PFC Desaturation
T921_O: Inverter Fault - Comp. Overcurrent
T922_O: Inverter Fault - PIM Temp Foldback
T923_O: Inverter Fault - High Refrig Pressure
A924_O: Inverter Fault - Board Temp
A925_O: Inverter Fault - Compr. Model Unknown
A926_O: Inverter Fault - HP Sensor Not Configured
A927_O: Inverter Fault - Drive Configuration
A928_O: Locked Out - See History Faults
A929_O: 240V Missing or Inverter Comm Failure
T931_O: Fan Fault Phase Over Current
T932_O: Fan Fault Phase Current Imbalance
T933_O: Fan Fault Motor Over/Under Speed
T934_O: Fan Fault U-Phase Over Current
T935_O: Fan Fault V-Phase Over Current
T936_O: Fan Fault W-Phase Over Current
T937_O: Fan Fault Module Over Current
T938_O: Fan Fault Loss of Phase
T939_O: Fan Fault Loss of Control
T941_O: Fan Fault Start Up Fault
T942_O: Fan Fault Module Temp High
T943_O: Fan Fault Module Over Temperature
T944_O: Inverter Fault - Envelope Protection
T945_O: Inverter Fault - PFC Overcurrent
T946_O: Inverter Fault - DC Bus Overvoltage
T947_O: Inverter Fault - DC Bus Undervoltage
A948_O: Inverter Fault - AC Input Overvoltage
A949_O: Configuration Data Restore Failure
T949_O: Backup Ht-Amb Temp Too Low for HP
A950_O: Configuration Data Restore Failure
A951_O: Memory Card Config Data Write Failure
T952_O: Outdoor Temperature Thermistor Failure
A953_O: Coil Temperature Thermistor Failure
A954_O: Suction Temperature Thermistor Failure
T955_O: Compressor Temp Thermistor Failure
A956_O: Suction Pressure Sensor Failure
A957_O: Low Refrigerant Pressure
T957_O: Low Refrigerant Pressure
A958_O: High Refrigerant Pressure
T958_O: High Refrigerant Pressure
T959_O: Compressor Locked Rotor - Lockout
A960_O: Compressor Locked Rotor - Lockout
T961_O: Discharge Temp Thermistor Failure
A962_O: Compressor U-Phase Over Current
A963_O: Inverter Fault - AC Input Undervoltage
T964_O: Inverter Fault - PIM Over-temp
T965_O: Inverter Fault - PFC Over-temp
A966_O: Inverter Fault - Lost Rotor Position
T967_O: Inverter Fault - Low Line Current Trip
T968_O: Inverter Fault - Line Sync Timeout
T969_O: Loss of Discharge Temperature Protection
A970_O: Inverter/Compressor Mismatch
T971_O: Compressor Lube Protection
T972_O: Compressor Discharge Temp High
T973_O: Stator Heat Overcurrent
T974_O: Line Current Trip
A975_O: Contactor Stuck On
T976_O: Fan Phase Current Low Trip
T977_O: Fan Inrush Relay Not Closed
A979_O: Compressor Over/Under Speed
A980_O: Fan Self Check Fault
T981_O: Fan Overcurrent Trip
T982_O: Fan Overvoltage Trip
T983_O: Fan Undervoltage Fault
T984_O: Fan Locked Rotor Fault
A985_O: Fan Self Check Fault
T986_O: High Refrigerant Pressure Envelope
A987_O: Compressor Loss of Phase
A988_O: Compressor Control Lost
A989_O: Charge Relay Open
A991_O: Compressor V-Phase Over Current
A992_O: Compressor W-Phase Over Current
A993_O: Compressor Module Over Current
A994_O: Compressor Prameter Fault
T995_O: IPM OVercurrent Trip
T996_O: Low Side Overcurrent Trip
T997_O: High Side Overcurrent Trip
A998_O: Fan Motor Parameter Fault
T999_O: Fan Motor Phase Imbalance